logo
Guangzhou Sande Electric Co.,Ltd.
이메일 Sales01@sande-elec.com TEL : 86--18620505228
> 상품 > 자동화 예비 부품 >
RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New
  • RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New
  • RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New
  • RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New
  • RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New
  • RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New

RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New

원래 장소 멕시코
브랜드 이름 Honeywell
인증 CE RoHS
모델 번호 RM7890A1015
제품 세부정보
상표:
하니웰
모델:
RM7890A1015
제품 유형:
버너 제어 릴레이 모듈
시리즈:
7800 시리즈
제어 유형:
온-오프 기본 제어
전압:
120 Vac
특징:
셔터 드라이브 포함
범주:
버너 관리 릴레이 모듈
보증:
1년
결제 및 배송 조건
최소 주문 수량
1
가격
USD 400-550 / piece
포장 세부 사항
오리지널 포장
배달 시간
2 일
지불 조건
L/C,D/A,D/P,T/T,웨스턴 유니온
공급 능력
일 당 100 PC
제품 설명
RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New
Honeywell RM7890A1015 On-Off Primary Burner Control
Product Overview

The Honeywell RM7890A1015 is an on-off primary burner control designed for automatically fired single-burner applications. This microprocessor-based integrated burner control features 120 Vac, 50/60 Hz operation with intermittent pilot functionality and intermittent main flame establishing period, offering either 4-second or 10-second pilot flame establishing period options.

Item Value
Brand Honeywell
Part Number RM7890A1015
Product Type On-Off Primary Burner Control
Voltage / Frequency 120 Vac, 50/60 Hz
Pilot Type Intermittent pilot
Main Flame Establishing Period Intermittent
Pilot Flame Establishing Period 4 second or 10 second
Typical Use Burner control and flame supervision
Professional Application Notes

The RM7890A1015 is ideally suited for single-burner automatic firing control applications where exact model number matching is critical during maintenance or system restoration.

  • Essential for burner management service and control-panel replacement planning
  • Ideal for legacy combustion-system spare inventory
  • Critical timing behavior and burner-sequencing logic compatibility
  • Preferred by combustion technicians for precise model replacement
Frequently Asked Questions
What is the clearest product name for RM7890A1015?

The clearest product name is On-Off Primary Burner Control. This terminology accurately reflects the part's function and appears in model-specific product listings.

Why is the intermittent pilot note important?

Pilot strategy is a key identity marker for burner relay modules. Combustion technicians verify whether a control uses intermittent or interrupted pilot logic before replacement, making this detail essential for practical application.

Why should the 4 or 10 second pilot flame establishing period be listed?

Burner-control timing is integral to the module's functional identity. These timing details help maintenance teams validate that replacements align with existing burner sequence and control expectations during repair work.

Is 120 Vac, 50/60 Hz important for the listing?

Yes. Voltage and frequency are essential selection criteria for this class of burner control. Including these specifications helps buyers confirm they are reviewing the correct module before proceeding to sequence and pilot details.

What kind of buyer usually searches for this control?

This model is primarily sought by burner technicians, boiler-control contractors, industrial combustion-service providers, and maintenance buyers replacing installed Honeywell burner controls by exact model number. These professionals require precise sequence and timing information over general product descriptions.

RM7890 A Honeywell 1015 Burner Control RM7890A1015 Genuine New 0

언제든 저희에게 연락하세요

+86 18620505228
10/F, Jia Yue Building, Chebei Road, Tianhe 지구, 광저우, 중국
문의 사항을 직접 보내주세요.